---
title: "Assay Management Configuration v3.0.3"
canonical: "https://servicedesk.maxgeo.com/space/DS/1436385335/Assay+Management+Configuration+v3.0.3"
format: markdown
---
> Macro (toc)

# Import Post-Processing Schemes

 

An Import Post-Processing Scheme is a logical listing of tables that the incoming assays will be merged to. The Default Post Processing scheme is configured in the standard MDS

Additional Import Post Processing schemes may need to be configured if multiple normalised assay tables are utilised. The configuration is in Assay Manager > Assay Configuration

![image-20241008-041747.png](media://0d8dd1e5-d6e7-4420-982d-77f5386c7558)

# Below Detection Treatment

 

In **Assay Manager > Assay Configuration** is the setting for the **Below Detection Treatment.**

The detection limit can be set to either –1 times the lower detection limit or to half the lower detection limit.

**WARNING: Do not change the handling of the BDL results unless you are prepared to update and re-rank the entire data- base.**

# Lab Checks and Standards

 

It is recommended that the labs report the checks and standards that they use for quality control and include the results in the results file.  Most labs have a prefix or suffix which identifies lab standards and lab repeats

The stored procedures will process standards and lab QC samples by creating a unique SampleID if necessary and populating the appropriate sample tables with SampleIDs.

The procedure references a library table, tblSYSIncomingDataMasks, which must be configured to suit the client, with the Labcodes, QC_Categories and StandardIDs that are relevant to the client.

![image-20241008-041929.png](media://e9a3fb88-2e06-4248-a0a1-946708b5b6fa)

**The Process has 3 steps:**

·         **Setting up Incoming Data Masks:**

This process identifies which records are lab QC results, and configures how the samples are to be processed.

·         **Updating libraries: Standards Reference and QC Category**

Adds the relevant records to the library tables so that the samples can be inserted into the standard sample table or the sample QC table

·         **Running the SP Data Driver**

Runs the process to update the sample ids in the incoming assay table and populate the relevant sample tables with the sample ID

# Setting up the Incoming Data Masks

The table tblSYSIncomingDataMasks is populated with the identifiers for the various QC data supplied by the lab.This information is generally supplied at the end of the lab file. The following notes detail how to populate this table. These settings can be found in Assay Manager > Library Tables.

![image-20241008-042022.png](media://2be72338-bfe6-42b5-917a-07a2e4bd4ff8)

The % is the wild card for this stored procedure.

 Note: Care must be taken when creating masks using wild cards to prevent incorrect identification.  
For example: If %OREAS 360% and %OREAS 360a% are both active then all results will report to the first mask.

 

**Identifier: **This uses wildcards to isolate the key identifier which will indicate that the sample is a lab dup or standard.

 **Lab Code:** The code of the lab as stated in the database library table tblSYSAssLab.

 **QC Category: **The QC_Category of the lab check as stated in the table tblLIBQCCategory. Do not populate for “identifiers” that relate to standards. Is Standard: Flag if it is a standard (0 = no, -1 = yes). If this is false then the stored procedure will assume that it is a QC sample.

 **StandardID: **Populate with the Standard ID for “identifiers” that related to standards. Leave blank for “identifiers” that are QCsamples. Not essential to populate.

 **Append batch no**: Flag (0 = no, -1 = yes) to append the Batch_No to the SampleID. If the standards in the lab file don’t have the Batch_No attached, then set flag to yes. This will prevent duplication of standard SampleIDs, which must be avoided. Only relates to standards, and must be set to no (0) for QC Samples.

 **Add Lab to BLANK**: Flag (0 = no, -1 = yes) to append the lab code to the StandardID where the StandardID = Blank. This enables the analysis (in QAQCR) of the Blanks from different labs on separate charts, rather than grouping all of the blanks from all labs together. This flag will add a new record to tblSYSQCReference where necessary (e.g., Blank_ALS_VAN, or Blank_SGS_VAN). Relates only to standard “BLANK”

 **STD nonUnique**: Flag (0 = no (SampleID is unique), -1 = yes (SampleID is not unique). If the standard SampleIDs in the lab file are not unique, then this flag generates a unique sample Id by adding the SourceRowNumber to the SampleID. This flag is typically set to no (0) for standard SampleIDs such as “ST01: ST02:” It is generally necessary to set this flag to yes (-1) for standard SampleIDs such as “ST:” without a unique number, or where SampleIDs = StandardID and do not have any prefix (such as “Blank”, “Sarm7B”), and are repeated in the laboratory file. Relates only to standard identifiers.

# Setting up the Libraries

**Repeats. **The QC Category is linked to the library LIB QC Category (tblSYSQCCategory). Any code entered into the Incoming Data Masks table QC_Category must first be entered to QC Category.

**Standards**: All Standard Ids need to be added to the library Standard reference (tblSYSQCStandardReference). These settings can be found in Assay Manager > Library Tables.